Lenze · E94AYCEO communication module (EtherNet/IP™) · Communication Manual · DMS 3.0 EN · 12/2013 · TD17 38
6 Commissioning
6.3 Setting the IP configuration of the Servo Drive 9400
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
6.3.1 Setting via the EtherNet/IP configurator of the »Engineer«
How to set the IP parameters via the EtherNet/IP configurator:
1. Execute the menu command Online PROFINET /EtherNet/IP configurator addresses ....
The Assign IP addresses dialog window is opened and all Lenze EtherNet/IP nodes
connected are listed.
Note!
• Changes in the IP parameters will become effective immediately.
• An existing IP connection to the Servo Drive 9400 will be interrupted.
• This procedure cannot be applied if the network is configured by a BOOTP/DHCP
server.
Setting via a BOOTP/DHCP server
( 42) (C13005 / C14005)