Lenze · E94AYCEO communication module (EtherNet/IP™) · Communication Manual · DMS 3.0 EN · 12/2013 · TD17 38
6 Commissioning
6.3 Setting the IP configuration of the Servo Drive 9400
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
6.3.1 Setting via the EtherNet/IP configurator of the »Engineer«
How to set the IP parameters via the EtherNet/IP configurator:
1. Execute the menu command Online PROFINET /EtherNet/IP configurator addresses ....
The Assign IP addresses dialog window is opened and all Lenze EtherNet/IP nodes
connected are listed.
Note!
Changes in the IP parameters will become effective immediately.
An existing IP connection to the Servo Drive 9400 will be interrupted.
This procedure cannot be applied if the network is configured by a BOOTP/DHCP
server.
Setting via a BOOTP/DHCP server
( 42) (C13005 / C14005)