6 Commissioning
6.3 Setting the IP configuration of the Servo Drive 9400
39
Lenze · E94AYCEO communication module (EtherNet/IP™) · Communication Manual · DMS 3.0 EN · 12/2013 · TD17
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
2. A double-click on an EtherNet/IP node opens the Configure nodes dialog window.
Here you can set the IP parameters.
3. Click on Transferred.
The IP configuration is transferred to the corresponding EtherNet/IP node.
The communication module carries out a stack reset.
The IP parameters are written to codes C13000
/ C14000 (IP address), C13001 / C14001
(subnet mask) und C13002
/ C14002 (gateway address).
•Code C13005
/ C14005 (IP configuration reference) is set to ’0: Saved address’ to ensure
that the address transferred can be used.
Tip!
Check whether the configuration has been transferred successfully.
For this purpose, open the Assign IP addresses dialog window (see step 1) and click on the
Find device button.