Lenze · E94AYCEO communication module (EtherNet/IP™) · Communication Manual · DMS 3.0 EN · 12/2013 · TD17 40
6 Commissioning
6.3 Setting the IP configuration of the Servo Drive 9400
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
6.3.2 Setting via codes in the »Engineer«
You can also set the IP parameters manually in the »Engineer« under the Settings tab. The values
will be transferred to the corresponding codes.
How to activate changed settings in the »Engineer«:
1. Execute device command C00002 = "11: Save all parameter sets".
The current IP configuration is stored in the memory module of the drive.
2. Carry out a "Type 0 reset" for the Identity Object (1 / 0x01)
( 121) of the node, or switch the
voltage supply of the communication module off and on again.
Settings Description
IP Config Control Selection (C13005
/ C14005) of how the IP configuration is to be effected:
0: The IP configuration currently stored in the communication module is
used.
1: The IP configuration is assigned by a BOOTP server using the BOOTP.
2: The IP configuration is assigned by a DHCP server using the DHCP.
IP Address Setting the IP address (C13000
/ C14000)
Subnet mask Setting the subnet mask (C13001
/ C14001)
Gateway Address Setting the gateway address (C13002
/ C14002)
Multicast IP Start Address Setting of the multicast IP start address (C13006
/ C14006)
Setting the multicast configuration
( 43)
Multicast Config TTL Value Setting of the multicast TTL value (C13019
/ C14019)