EasyManua.ls Logo

Lenze i550 Series - Page 141

Lenze i550 Series
264 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Inverter i550-C75/400-3 i550-C90/400-3 i550-C110/400-3
Rated power kW P
N
90 110 132
Rated power hp P
N
125 150 175
Mains voltage range 3/PE AC 340 V ... 528 V, 45 Hz ... 65 Hz
Output voltage 3 AC 0-400/480 V
Rated mains current
without mains choke A I
r, AC
- - -
with mains choke A I
r, AC
160 200 234
Apparent output power kVA A
ON
121 145 171
Rated output current
2 kHz A I
OUT
180 216 254
4 kHz A I
OUT
180 216 254
8 kHz A I
OUT
- - -
16 kHz A I
OUT
- - -
Power loss
2 kHz W 1841 2203 2589
4 kHz W 1961 2348 2760
8 kHz W - - -
16 kHz W - - -
at inverter disablecontroller
inhibit
W 30 30 30
Overcurrent cycle 180 s
Max. output current A I
max, out
225 270 318
Overload me s t
ol
60 60 60
Recovery me s t
re
120 120 120
Max. output current during the
recovery me
A 113 135 159
Overcurrent cycle 15 s
Max. output current A I
max, out
300 360 424
Overload me s t
ol
3 3 3
Recovery me s t
re
12 12 12
Max. output current during the
recovery me
A 113 135 159
Cyclic mains switching 1 me per minute
Brake chopper
Max. output current A I
max, 1
166 333 333
Min. brake resistance Ω R
min
4.7 2.4 2.4
Max. motor cable length shielded
without EMC category m 100 100 100
Category C1 (2 kHz, 4 kHz, 8
kHz)
m - - -
Category C2 (2 kHz, 4 kHz, 8
kHz)
m 20 20 20
Category C3 (2 kHz, 4 kHz, 8
kHz)
m 100 100 100
Weight kg 24 35.6 35.6
Weight lb 53 78.5 78.5
Technical data
3-phase mains connecon 400 V "Light Duty"
Rated data