PE connecon
Inverter i550-C0.25/230-1 i550-C0.25/230-2 i550-C0.37/230-1 i550-C0.37/230-2
Connecon PE
Connecon type PE screw
Max. cable cross-secon mm² 6 6 6 6
Max. cable cross-secon AWG 10 10 10 10
Stripping length mm 10 10 10 10
Stripping length inch 0.39 0.39 0.39 0.39
Tightening torque Nm 2 2 2 2
Tightening torque lb-in 18 18 18 18
Required tool Torx 20
PE connecon
Inverter i550-C0.55/230-1 i550-C0.55/230-2 i550-C0.75/230-1 i550-C0.75/230-2
Connecon PE
Connecon type PE screw
Max. cable cross-secon mm² 6 6 6 6
Max. cable cross-secon AWG 10 10 10 10
Stripping length mm 10 10 10 10
Stripping length inch 0.39 0.39 0.39 0.39
Tightening torque Nm 2 2 2 2
Tightening torque lb-in 18 18 18 18
Required tool Torx 20
PE connecon
Inverter i550-C1.1/230-1 i550-C1.1/230-2 i550-C1.5/230-1 i550-C1.5/230-2
Connecon PE
Connecon type PE screw
Max. cable cross-secon mm² 6 6 6 6
Max. cable cross-secon AWG 10 10 10 10
Stripping length mm 10 10 10 10
Stripping length inch 0.39 0.39 0.39 0.39
Tightening torque Nm 2 2 2 2
Tightening torque lb-in 18 18 18 18
Required tool Torx 20
PE connecon
Inverter i550-C2.2/230-1 i550-C2.2/230-2
Connecon PE
Connecon type PE screw
Max. cable cross-secon mm² 6 6
Max. cable cross-secon AWG 10 10
Stripping length mm 10 10
Stripping length inch 0.39 0.39
Tightening torque Nm 2 2
Tightening torque lb-in 18 18
Required tool Torx 20
Technical data
1-phase mains connecon 230/240 V
Terminal data
94