Technical data
General data and operating conditions
4
l
19
LDEDS−CCU210B EN 4.0
4 Technical data
4.1 General data and operating conditions
General data
Conformity and approval
Conformity
CE
2006/95/EC Low−Voltage Directive
93/68/EEC EMC Directive (basis 89/336/EEC)
Protection of persons and equipment
Degree of protection EN 60529
IP54
Cover all unused connectors with protective caps or dummy
plugs.
The cover over X60/X61 has to be available.
Earth leakage current EN 61800−5−1 < 3.5 mA
Insulation of control
circuits
EN 61800−5−1 Safe mains isolation by double (reinforced) insulation
Insulation resistance EN 61800−5−1
< 2000 m site altitude: overvoltage category III
> 2000 m site altitude: overvoltage category II
Protective measures Against motor overtemperature (input for PTC or thermal
contact), overcurrent at output
EMC
Noise emission EN 61800−3
Compliance with the limit values for the 2. environment
(industrial premises): category C3
Noise immunity EN 61800−3 Compliance with the limit values for the 2. environment
(industrial premises): category C3