EasyManua.ls Logo

Lenze LDEC Series - Assignment Logic

Lenze LDEC Series
110 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Function library
Digital output signals
Assignment logic
8
l
50
LDEDS−CCU210B EN 4.0
8.4.2 Assignment logic
In the assignment logic (C0415) you assign internal status signals to the message bar and
the digital outputs.
Codes for parameter setting
Code Possible settings Description
No. ñò < Byte Lenze Selection
C0415 Linking internal status signals to
digital output signal ...
^ 50
1
RW EXT 4
0 Not assigned ...Digital output DOUT1
2 0 Not assigned ...Digital output DOUT2
3 0 Not assigned Reserved
4 0 Not assigned Reserved
5 0 Not assigned ... Message bar1 positive half wave
6 0 Not assigned ... Message bar1 negative half wave
Possible values
0 Not assigned
1 Motor V1 active
2 Motor V2 active
3 Motor V3 active
4 Motor V4 active
5 Motor V5 active
6 Motor V6 active
7 Motor V7 active
8 Motor V8 active
9 Motor CCW rotation active
10 Reserved
11 Fault active
12 Reserved
13 Frequency inverter: parameter set 2
active
14 Reserved
15 Brake is open
16 Stop 1 active
17 Stop 2 active
18 Stop 3 active
19 Stop 4 active
20 Frequency limitation 1 active
21 Frequency limitation 2 active
22 Frequency limitation 3 active
23 Frequency limitation 4 active
24 SensoPart: parameter set 2 active
25 Reserved
... ...
29 Reserved
30 HWC code range active
31 Reserved