Electrical installation
Mains connection
6
l
31
LDEDS−CCU210B EN 4.0
6.3 Mains connection
CCU210_002C
X1 − Mains connection
Pin Connection Description Data
Connector: FASTON 6.3 x 0.8 mm flat
connector, 10−pole
1 L1 Phase L1
3/PE/PEN AC 360 V − 0 % ... 528 V + 0 %
45 Hz − 0 % ... 65 Hz + 0 %
2 L2 Phase L2
3 L3 Phase L3
4 + PE PE conductor
5 n.c. Not assigned
6 n.c. Not assigned
7 SS1 Control bar 1
8 n.c. Not assigned
9 n.c. Not assigned
10 MS1 Message bar 1
The SS2 control bar is assigned according to customer’s specifications. (see project documentation)