Function library
Motor control
"Motor speed V1−V8" function
8
l
53
LDEDS−CCU210B EN 4.0
DescriptionPossible settingsCode
SelectionLenzeByte<ñòNo.
C0013 Deceleration time for ...
^ 52
1
RW EXT 4
50
1 {Hz/s} 255
... V1
2 50 ... V2
3 50 ... V3
4 50 ... V4
5 50 ... V5
6 50 ... V6
7 50 ... V7
8 50 ... V8
C0014 RW EXT 4 80
Deceleration time for quick stop
functions:
l On/Off switch
l Error
l SensoPart trip−out
^ 52
1 {Hz/s} 255
C0420 RW EXT 4 0
Deceleration time:
start−up after mains connection
V0 ð Vx
^ 52
0 {ms} 20000
C0421 RW EXT 4 0
Deceleration time:
start−up after On/Off switch to ON
V0 ð Vx
^ 52
0 {ms} 20000