5.3.2
Pin
10:
Servo
Power
On
When
the input is
active,
the
Controller
is
enabled
and
the
Reference
signal
is
acti
-
vated
at
zero
until
movement
takes
place.
When
the input is not active, the
control
automatically
terminates
the
movement.
Input
-
Servo
Power
ON
The
input
at
X2
pin
10
is
used
for
instant
interruption
of
the
program
and
movement.
When
open:
-
The
Reference
is
zeroed
instantly
(Actual
=
Required
Position)
-
Servo
Enable
and
Ready
Outputs are
opened
-
Error
E06
(power
loss) is
reported
-
Ihe
following
error monitor
is
cancelled
When
closed:
-
E06
is
cancelled
-
Servo
Enable
and
Ready
Outputs are
restored
-
An
interrupted program
is
restarted
with
a
positive
edge
on
E5
-
An
interrupted
automatic
movement
is
completed
-
An
interrupted
manual
movement
must be
restarted
with
the
key
5/11