9.
9.
Error
Messages and Correction
Any
error
arising
is
displayed
both
on
the
7-Segment
display
of
the
SX-1
and
on
the
PT-1.
The
SX-1
sequentially displays
the
error
by
a
letter
„E“
tollowed
by
a
2-digit
number.
The
tollowing
errors
are
possible:
Error
Code
Meaning
Possible
Cause
and
Remedy
00
Internal
tault
Press
Reset
key
01
End
Switch
approached
Negative
Limit
Return
drive
to
working
area
02
End
Switch
approached
Positive
Limit
Return
drive
to
working
area
03
Selected
SX-1
missing
Check
24
Vdc External
supply:
Enable
SX-1,
Connector
X2
pin
2,
andon
ConnectorXl
pins
13/25.
04
Position
Feedback
Check
power
supply
tor encoder
05
Gain
tactor
out
of
tolerance;
motor
not
tollowing
the
control
command (incorrect
rpm/vo
It)
Motor
overloaded:
check
dimensio
ning,
acceleration or velocity
too
high:
reduce.
Di
rection
i
ncorrect:
reverse
polarity
(P12
or
P13)
06
Servo
Power
tailure
Connector
X2
Pin
10:
external
power
supply
missing
07
Encoder
watchdog
No
encoder
pulses
present
08
lnvalid
Control
command Internal
error
09
Left
limit
of
travel
is
reached
Check
Program;
Home;
Check
-ve
Software
limit P9
10
Right
limit
of
travel
is
reached
Check
Program;
Home;
Check
+ve
Software
limit
P1O
9/1