6.1.2
____
6.1.2
Test
Mode Operation
The
test
mode
is
provided
for
use
during
commissioning
and
for
servicing
and
trouble-
shooting.
The
operati
ng
mode
is
pre-selected
by
Parameter
P24
=0,
but
this
is
not
operable
until
after
the
control
is reset.
NOTE:
After
the
test
session, then
P24
must
be
set
to
a
non-zero
value.
In
the
servo
test
mode, the
direct speed
(velocity)
reference signal
is
given
to
the
servo.
All
modes can
be
used.
All
ECL program instructions
may
be
used,
with
the
exception
of
Touch
Probe
and
„Actual
Position“
instructions.
NOTE:
There
is
no
monitoring
of
the
Actual
Position
and
Software
Limits in this mode.
The
internal
Commanded
Position
is
indicated
as
the Actual
Position.
NOTE!
The Position
Loop is
not
active
in
the
Test
mode.
A
servo-controlled
stop
cannot
be
guaranteed
in
this
mode
(switch
the
brake).