Mounting / Installation (all device models)
Leuze electronic DDLS 200 13
TNT 35/7-24V
• In the case of a frequency-offset arrangement, the distance between two parallel transmission
paths must not be less than
• 400 mm (DDLS 200/30…)
• 300 mm (DDLS 200/80…)
• 300 mm (DDLS 200/120…)
• 500 mm (DDLS 200/200…)
• 700 mm (DDLS 200/300…)
• 700 mm (DDLS 200/500…)
• In the case of identical frequency arrangement, the distance between two parallel transmission
paths must be at least
• 400mm + tan (1.5°) • operating range (DDLS 200/30…)
• 300mm + tan (1.0°) • operating range (DDLS 200/80…)
• 300mm + tan (0.5°) • operating range (DDLS 200/120…)
• 500mm + tan (0.5°) • operating range (DDLS 200/200…)
• 700mm + tan (0.5°) • operating range (DDLS 200/300…)
• 700mm + tan (0.5°) • operating range (DDLS 200/500…)