Mounting / Installation (all device models)
Leuze electronic DDLS 200 15
TNT 35/7-24V
The following table shows the maximum number of optical transmission paths for cascading.
Bus system
Max. number of optical
transmission paths for
cascading
Comment
PROFIBUS (with retiming) 3
Attention:
PROFIBUS FMS is a multi-master bus
RS 485 (without retiming) 2
INTERBUS 500kBit
(RS 422)
3
INTERBUS FOC 3 Applies for 500kBit and 2MBit
RIO 3
1)
1) See remarks in the respective chapters of the individual bus systems about the switch position fil-
tered/not filtered depending on the transmission rate.
DH+
3
1)
Attention:
DH+ may be a multi-master bus
DeviceNet 3
Depends significantly on the configura-
tion of the master and on the require-
ments of the plant (time behavior).
CANopen 3
Ethernet 3
NOTE
The individual delay time of the optical transmission path is specified in the chapters of the
individual bus systems and depends on the type, switch position, and transmission rate.
DDLS200_E.book Seite 15 Mittwoch, 19. Februar 2020 12:22 12