Lexicon
4-7
7. Move the Audio Input cable to Audio Input #2 and repeat the test.
8. Repeat the test on the remaining Input /Outputs pairs 3-4,5-6, and 7-8.
Digital In To Analog Out Frequency Response Test:
Note: Change the Clock Source and Inputs to AES - see Audio/Functional Tests Setup.
1. Disable all Filters on the distortion analyzer
2. Connect a balanced XLR audio cable between the digital function generator and the 960L # 1-2 AES
Input.
3. Connect a balanced XLR audio cable between the 960L # 1 Audio Output and the distortion analyzer.
4. Apply a 1kHz sinewave @ -1 dBFS.
5. Set the Analyzer for a 0dB reference (@1khz)
6. Sweep the oscillator from 20Hz to 20kHz and verify the level is +/- 1dBr throughout the sweep.
7. Move the audio output cable to the # 2 Output and repeat the test.
8. Repeat the test for the remaining Input /Outputs pairs 3-4,5-6, and 7-8.
THD+N Measurement:
Analog In to Analog Out THD+N Test:
Note: Change the Clock Source to Internal and Inputs to Analog - see Audio/Functional Tests Setup.
1. Connect a balanced XLR audio cable between the low distortion oscillator and the 960L # 1 Audio
Input.
2. Connect a balanced XLR audio cable between the 960L # 1 Audio Output and the distortion analyzer.
3. Apply a 997Hz sinewave @ 9.75 VRMS.
4. Set the distortion analyzer to measure THD+N.
5. Enable the Audio Band Pass filter on the distortion analyzer.
6. Verify the output THD+N on the Analyzer is < 0.002%.
7. Repeat the rest for the remaining Input /Outputs 2-8.
Analog In to Digital Out THD+N Test:
1. Connect a balanced XLR audio cable between the low distortion oscillator and the 960L # 1 Audio
Input.
2. Connect a balanced XLR audio cable between the 960L # 1-2 AES Output and the digital distortion
analyzer.
3. Apply a 997Hz sinewave @ 10.94 VRMS.
4. Set the distortion analyzer to measure THD+N.
5. Enable the Audio Band Pass filter on the distortion analyzer.
6. Verify the output THD+N on the Analyzer is < -94 dBFS.
7. Move the audio input cable to the # 2 Input and repeat the test.
8. Repeat the test for the remaining Input /Outputs pairs 3-4,5-6, and 7-8.
Digital In to Analog Out THD+N Test:
Note: Change the Clock Source and Inputs to AES - see Audio/Functional Tests Setup.
1. Connect a balanced XLR audio cable between the digital function generator and the 960L # 1-2 AES
Input.
2. Connect a balanced XLR audio cable between the 960L # 1 Audio Output and the distortion analyzer.
3. Apply a 997Hz sinewave @ -1 dBFS.
4. Set the distortion analyzer to measure THD+N.
5. Enable the Audio Band Pass filter on the distortion analyzer.
6. Verify the output THD+N on the Analyzer is < -94 dBFS.
7. Move the audio output cable to the # 2 Output and repeat the test.
8. Repeat the test for the remaining Input /Outputs pairs 3-4,5-6, and 7-8.

Table of Contents

Other manuals for Lexicon 960L

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lexicon 960L and is the answer not in the manual?

Lexicon 960L Specifications

General IconGeneral
BrandLexicon
Model960L
CategoryRecording Equipment
LanguageEnglish

Related product manuals