Maintenance
76
300554859_002_C0 - 11/2016 - © Leybold
The pump will have to be disassembled if there is more extensive contamina-
tion. The Leybold Customer Service Department will have to be consulted
here in all cases.
5.2 Oil of the Rotary Vane Pump
The TRIVAC or SOGEVAC requires for proper operation sufficiently fresh and
suitable oil.
The oil level of the backing pump must be checked at least once a week.
The oil must be changed when appears contaminated, chemically changed
or mechanically worn out. When the oil contaminates too rapidly, install a
dust and/or an oil filter.
Precise information on this topic and on other maintenance works is provided
in the Operating Instructions for the rotary vane pump.
With the gas ballast valve open, a larger quantity of oil escapes from the rota-
ry vane pump so that the oil level will have to be checked more frequently
under such operating conditions.
5.3 Removing the Backing pump
Each foot on the backing pump is bolted to the base plate by a bolt and
three nuts. The nut accessible from above is bonded to the bolt; the two nuts
accessible from below are counter-tightened.
To remove the backing pump, un-screw the counter-tightened nuts beneath
the base plate, and lift off the pump.
After removing the backing pump, seal both connecting flanges.
5.4 Leybold Service
Whenever you send us in equipment, indicate whether the equipment is con-
taminated or is free of substances which could pose a health hazard. If it is
con taminated, specify exactly which substances are in volved. You must use
the form we have prepared for this purpose.
A copy of the form has been reproduced at the end of these Operating
Instructions: “Declaration of Contamination for Compressors, Vacuum Pumps
and Components”. Another suitable form is available from
www.leybold.com Documents Download Documents.
Attach the form to each contaminated pump.
This statement detailing the type of contamination is required to satisfy legal
requirements and for the protection of our employees.
We must return to the sender any equipment which is not accompanied by a
contamination statement.
Contamination