EasyManuals Logo

LEYBOLD TURBOLAB 80 User Manual

LEYBOLD TURBOLAB 80
86 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #26 background imageLoading...
Page #26 background image
Installation
25
300554859_002_C0 - 11/2016 - © Leybold
3 Installation
3.1 Placement
Table Pump Systems
Carry or lift the pump system only by lifting it at the frame or at the crane eye.
Install the pump system on a level, smooth surface, which is sufficiently large.
Remove the transport securing screw.
Cart Pump Systems
Unpack the pump system by lifting it at the crane eye. Afterwards unscrew
the crane eye and put the cover supplied onto the column. Install the pump
system on a level, smooth surface; lock the front castors.
Cart Pump Systems with TRIVAC
Connect TRIVAC pump with the included power cable. The connection to the
pumping system is already given. The cable is hanging loosely next to the
pumping system.
See supplement for operating instructions BB 300623641.
All Pump Systems
The high-vacuum connection must be as close as possible to the vacuum
vessel.
Install the pump system such that a clearance of at least 10 cm is left on
each side of the pump system for ventilation.
Fig. 3.1 Transport protection for bench-top pump systems
Screw for securing
during transport
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the LEYBOLD TURBOLAB 80 and is the answer not in the manual?

LEYBOLD TURBOLAB 80 Specifications

General IconGeneral
BrandLEYBOLD
ModelTURBOLAB 80
CategoryWater Pump
LanguageEnglish

Related product manuals