8-3 Icing Sensor Error (Er IS)
No Checking flow Result & SVC Action
1 Check for a loose connection.
2 Check the Blue to Blue.
<Display>
<CON101>
1>
0 _ Short Change the sensor
Check the resistance
of the defrost sensor
wires back to the
main PCB. If they are
Infinite Open open between the
ohms Main PCB and the
connector for the
icemaker it will be
necessary to replace
the refrigerator.
See
Check the Temp and
resistance Normal resistance (Table-I)
table
<Temperature table-l>
-22°F / -30°C 40 k_
-13°F / -25°C 30 k_
-4°F / -20°C 23 k_
5°F/-15°C 17 k_
14°F/-10°C 13 k_
23OF/ -5oc 10 k_
32OF/ OoC 8 k_
The sensor is determined by
the temperature.
For example, 23k£ indicates -4°F.
- 25 -