8-8 Condenser Fan Error (Er CF)
No Checking flow Result & SVC Action
1
2
3
4
Reset the unit and
Input Test I Mode.
(Push the button 1 time)
Check the fan rotating.
While an error code is displayed,
the fan is not working.
Check the Fan motor and surrounding.
Check the Fan motor voltage.
(1)Pin2, (2)Pin4, (3)Pin6
<CON7>
!i!i!i!i!i!i!i!i!iiiiiiiiii ! ii ii ilililililililililiiiii !iiii!,i!i!i!i!iiiiiiil
No airflow Check motor
Airflow Go to the 4
Rotate fan using your hand.
It feel stuck or locked up, change the motor.
(1) ~ (2) Below 10 V Change the PCB
(2) ~ (3) 0 or 5 V Change the motor