No LED operating condition Service guideline
1.
LED two - time repetiton (Stroke Trip)
•.on - on - off - on - on - off - on - on - off .. repeating
LED five - time repetiton (Piston Lock Trip)
Cause
PCB Parts
defect or
Compress
or
Connector
miss
connecting
(Piston
over run)
Piston
constraint
2,
3,
2,
•.on - on - on - on - on - off- on - on - on - on - on - off .. repeating 3.
1.
LED six - time repetiton (Current Trip) Circuit
over 2.
current
error
•.on - on - on - on - on - on - off - on - on - on - on - on - on - off • •repeating Or cycle 3.
error
LED seven- time repetiton (IPM Fault Trip)
PCB parts
defect
(IPM)
•.on - on - on - on - on - on - on - off - on - on -on - on - on - on- on - off ,,repeating
Please check, Whether
connector of
compressor is attached
rightly or not. after
power off
After the first action,
You check on normal
operation of
compressor.
If the same symptom
arises after the second
action, replace PCB
After resetting power,
check if it is running
normal
If the same symptom
arises after the first
action
If the same symptom
arises after the second
action, replace
compressor
After resetting power,
check if it is running
normal
If the same symptom
arises after the first
action
If the same symptom
arises after the second
action, replace
compressor
1. After resetting power,
check if it is running
normal
2. If the same symptom
arises after the first
action, replace PCB
- 60 -