Special Jack Error Codes on OneControl Touch Panel or OneControl App
To clear the error codes listed below:
1. Correct or otherwise repair the issue (see the table below).
NOTE: In order to clear the special jack error code the jacks need to be “homed.” In order to “home” jacks,
each jack must be able to retract a minimum of 6”.
NOTE: The Power Tongue Jack does not need to be “homed.” The Power Tongue Jack cannot be operated
from the OneControl Touch Panel or OneControl App while clearing the special jack error codes.
The Power Tongue Jack can be operated using the “RET/EXT” switch on the tongue jack during this
procedure.
2. Extend all jacks to reach the 6” of minimum retract needed.
A. Press “EXTEND” and “FRONT” to extend the front jacks (if required).Refer to “Operation -
OneControl Touch Panel” and “Operation - OneControl App.”
B. Press “EXTEND” and “REAR” to extend the rear jacks (if required). Refer to “Operation - OneControl
Touch Panel” and “Operation - OneControl App.”
3. Press “ENTER” to AUTO RETRACT. The jacks will retract until they reach the hard current limit. The
Power Tongue Jack will perform an automatic grounding during the AUTO RETRACT sequence.
4. The jacks are now “homed” and the special jack error code will be cleared.
Touch Panel
Message
What's Happening? What Should I Do?
***ERROR***
Left-Front Jack Fault
Right-Front Jack Fault
Left-Rear Jack Fault
Right-Rear Jack Fault
Tongue Jack Fault
Error at a specific jack (left front, right
front, left middle, right middle, left
rear, right rear, tongue). Hall signal
issue (open, short, malfunction or
loss of communication); open or
short circuit between controller and
motor.
Check voltage at the battery under load.
Check harness connections
at controller and at jack.
Check harness for damage.
Check fuses at controller.
Repair or replace as necessary.

Table of Contents

Other manuals for Lippert Components ground control TT

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lippert Components ground control TT and is the answer not in the manual?

Lippert Components ground control TT Specifications

General IconGeneral
BrandLippert Components
Modelground control TT
CategoryLifting Systems
LanguageEnglish

Related product manuals