VALVES
A2847-11 Solenoid-Operated


S1 Solenoid
LectroCount LCR-II
Gallons
Electro-Pnuematic
Preset Valve
Single Stage Electro-Pnuematic
Valve with V-7 Valve
S1 Solenoid
V-7 Valve
Electro-Pnuematic
Actuator
LectroCount LCR-II
Gallons


Single Stage

Single Stage Systems
Liquid Controls’ Valves Overview


and wired to the LCR-II at the factory. Electronic control

meter systems already in service. These valves will need

refer to the valve manual. This manual includes wiring
instructions for the valves.



operated valves close off and open the bypass pipes.

in order to open and close the control valve. These
solenoid-operated valves must be wired to the LCR-II
CPU board during installation.
Liquid Controls offers single stage and two stage
electronic valves. Single stage valves have one solenoid
valve (S1) and two positions—an open position and a
closed position. Two stage valves have two solenoid


by the S2 solenoid and initiated shortly before the
register reaches a preset value.
SINGLE STAGE VALVES
The three most common Liquid Controls meter systems



and an electro-pnuematic valve with an S1 solenoid.
A2847-11 Valve
This single stage control valve has a S1 solenoid-
operated valve located at the meeting point of three
external pipes: one pipe from the inlet side of the valve,

outlet side of the valve. This valve is typically used in

A2843 Valve and 3-Way Solenoid
The 3-way solenoid-operated valve—mounted directly

LCR-II—serves as a S1 solenoid-operated valve. The
3-way solenoid-operated valve is located at the meeting
point of two pipes from the vapor eliminator (one for




3
.
The LCR-II is also compatible with many other brands
and types of valves.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Liquid Controls LectroCount LCR-II E3655 Series and is the answer not in the manual?

Liquid Controls LectroCount LCR-II E3655 Series Specifications

General IconGeneral
BrandLiquid Controls
ModelLectroCount LCR-II E3655 Series
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals