EasyManua.ls Logo

Liquid Controls LectroCount LCR-II E3655 Series

Liquid Controls LectroCount LCR-II E3655 Series
36 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
19
VALVES
A2847-11 Solenoid-Operated


S1 Solenoid
LectroCount LCR-II
Gallons
Electro-Pnuematic
Preset Valve
Single Stage Electro-Pnuematic
Valve with V-7 Valve
S1 Solenoid
V-7 Valve
Electro-Pnuematic
Actuator
LectroCount LCR-II
Gallons


Single Stage

Single Stage Systems
Liquid Controls’ Valves Overview


and wired to the LCR-II at the factory. Electronic control

meter systems already in service. These valves will need

refer to the valve manual. This manual includes wiring
instructions for the valves.



operated valves close off and open the bypass pipes.

in order to open and close the control valve. These
solenoid-operated valves must be wired to the LCR-II
CPU board during installation.
Liquid Controls offers single stage and two stage
electronic valves. Single stage valves have one solenoid
valve (S1) and two positions—an open position and a
closed position. Two stage valves have two solenoid


by the S2 solenoid and initiated shortly before the
register reaches a preset value.
SINGLE STAGE VALVES
The three most common Liquid Controls meter systems



and an electro-pnuematic valve with an S1 solenoid.
A2847-11 Valve
This single stage control valve has a S1 solenoid-
operated valve located at the meeting point of three
external pipes: one pipe from the inlet side of the valve,

outlet side of the valve. This valve is typically used in

A2843 Valve and 3-Way Solenoid
The 3-way solenoid-operated valve—mounted directly

LCR-II—serves as a S1 solenoid-operated valve. The
3-way solenoid-operated valve is located at the meeting
point of two pipes from the vapor eliminator (one for




3
.
The LCR-II is also compatible with many other brands
and types of valves.