CHAPTER 7: OPERATION 7-17
QUICK LOAD SERVO III MI
Loading with fixed spindle liner (may be not visible)
This parameter allows to work in a specific mode, where a non-rotating spindle liner allows premature
shaft loading, to speed up the loading process. This parameter should only be used with a physical limiter
on the loading magazine to avoid the loading of longer bars, which could lead to damages on the lathe.
Please contact your LNS agent for further information on this application.
Feed rate for part feed out (may be not visible)
This parameter allows to adapt the feed rate to the actual weight of the bar, for example when feeding