MAINTENANCE
The PH360 is easy to maintain as 95% of the planer/
moulder is protected against rust. The maintenance
required, is mentioned below. Ensure that the power
to the planer/moulder is switched off before begin-
ning maintenance.
After each work session:
• Clean chips from the planer/moulder. Also re-
move any chips from under the planer/moulder.
• Clean any resin off the table. Use mineral spirit
if necessary. Lubricate the table with parafn oil,
for example.
MAINTAIN AT REGULAR INTERVALS AS
FOLLOWS
Lubricate these areas regularly:
• Feed roller Bushings.
• Sprockets, including top and bottom layers.
• The chain for setting table height.
• The chain driving the feed rollers.
• The two bars that the moveable slide runs on, as
well as the slide's trapezoidal thread.
• Cast iron table.
Check that all screws and bolt connections are tigh-
tened and that cables and electrical connectors are
in good condition.
USING OR STORING IN COLD OR DAMP
ENVIRONMENTS
If the planer will be stored in a cold or damp en-
vironment over a longer period, all corrosive parts
must be treated with a rust inhibitor. Cover the
planer.
Water can condense in closed spaces. Check that
the motors are dry inside by loosening the draining
plugs. Check the control panel box.