21
LOGOSOL PH360
MAINTENANCE
The PH360 is easy to maintain as 95% of the planer/
moulder is protected against rust. The maintenance
required, is mentioned below. Ensure that the power
to the planer/moulder is switched off before begin-
ning maintenance.
After each work session:
Clean chips from the planer/moulder. Also re-
move any chips from under the planer/moulder.
Clean any resin off the table. Use mineral spirit
if necessary. Lubricate the table with parafn oil,
for example.
MAINTAIN AT REGULAR INTERVALS AS
FOLLOWS
Lubricate these areas regularly:
Feed roller Bushings.
Sprockets, including top and bottom layers.
The chain for setting table height.
The chain driving the feed rollers.
The two bars that the moveable slide runs on, as
well as the slide's trapezoidal thread.
Cast iron table.
Check that all screws and bolt connections are tigh-
tened and that cables and electrical connectors are
in good condition.
USING OR STORING IN COLD OR DAMP
ENVIRONMENTS
If the planer will be stored in a cold or damp en-
vironment over a longer period, all corrosive parts
must be treated with a rust inhibitor. Cover the
planer.
Water can condense in closed spaces. Check that
the motors are dry inside by loosening the draining
plugs. Check the control panel box.