33
Function code 28 Function code 28
Length of data 0 Length of data 6
Checking Accumulation Decimal point
Scale division
Capacity
(
MMSB
)
Capacity
(
MSB
)
Capacity (LSB)
Checking Accumulation
6.4.3.3.19. Read the Calibration Coefficient
Request:Master Response:Slaver
Domain name
Data
(
hex
)
Domain name
Data
(
hex
)
Beginning code 7E Beginning code 7E
Address 01-63 Address 01-63
Function code 29 Function code 29
Length of data
0
Length of data
3
Checking Accumulation Calibration coefficient(MMSB)
Calibration coefficient(MSB)
Calibration coefficient(LSB)
Checking Accumulati
on
6.4.3.3.20. Set the Function Parameters
Request:Master Response:Slaver
Domain name Data(hex) Domain name Data(hex)
Beginning code 7E Beginning code 7E
Address 01-63 Address 01-63
Function code
30
Function code
30
Length of data 4 Length of data 1
Range of zero tracking Range of clearing to Status of