Charging Policy: The charging policy for LLM Gateway to decide the charging current for each
Loop EV-Flex EVSE.
Valid options are:
1.) UD (default): Uniform Distribution. The maximum amperage is divided by total numbers of charging EV, i.e.
each EV will use the same charging current.
2.) FIFS: First In First Serve.
Group ID: An identity of the LLM group. A slave with dierent group identity will be rejected when attempting to con-
nect to Gateway.
Group Size: The total number of Loop EV-Flex EVSEs in the LLM group. This value is only used in Gateway.
Max Amperage Grid Connection: Total ampere of each phase allowed loading for the group of
Loop EV-Flex EVSEs at the same time. This value is only used in Gateway.
Fallback Current: The fallback current when Client is not able to communicate with Gateway. Gateway will overwrite
fallback current in Client with its own value when Client connected to Gateway.
Note:
Any option followed by a star mark (*) means the setting need to reboot to take eect.
When these value changed and applied the web portal will display a reminder message
box for rebooting the charge point.