Cat. Faults Main causes Solutions
Battery is not charge
Abnormal wiring
Alternator failure
Lack of fan belt tension or
broken
Abnormal battery
Check the tightening state
of terminal and ground
Repair or replace
Adjust fan belt tension or
replace
Replace
Headlight is dark.
Battery capacity is low
Bad wiring and contact
Charge or replace
Check and repair
Headlight does not
Light bulb cut
-
off
Replace
Electric
System
Headlight does not
ON.
Light bulb cut
-
off
Fuse blown
Replace
Check the cause, and
replace
Horn does not sound.
Switch failure
Abnormal wiring
Horn failure
Replace
Repair
Replace
Turn signal Light does
not work.
Light bulb cut-off
Bad connection
Fuse blown
Replace
Tighten terminals
Check the cause, and
replace
Cold start aid indicator
does not ON. (option)
Relay or timer damaged
Bad connection of preheat
plug wiring
Replace
Check and tighten
Other illuminating and
Fuse blown
Check the cause, and
replace
5
5 5
5 - 33
Other illuminating and
indicator does not ON.
Light bulb cut-off
replace
Replace