5-11. Troubleshooting
Warning
To avoid injury due to sudden start, apply parking brake and place the
transmission gear in “Neutral” before checking and repairing.
Classific
ation
Problems Main causes Solutions
The start motor does
not turn when turning
the key switch.
Start safety switch is not
contacted.
PTO switch is not on “OFF”
position.
Discharge of battery
Terminal loosened
Depress the clutch pedal
fully
Place PTO switch on “OFF”
position
Charge or replace
Tighten
Engine
the key switch.
Terminal loosened
Key switch failure
Start motor failure
Tighten
Repair or replace
Repair or replace
The start motor turns
but the engine does
not start.
The battery is weak.
Bad ground
Improper viscosity of engine
oil
Air in fuel system
Fuel filter clogged
Error in engine body
Fuel cock closed
Charge or replace
Tighten the ground
Replace the oil with proper
viscosity.
Bleed the air
Wash or replace the filter
Repair
Open the cock
Engine revolution is
irregular.
Air in fuel system
Fuel filter clogged
Injection nozzle clogged
Fuel leakage
Bleed air
Clean or replace the filter
Repair or replace
Repair
5
5 5
5 - 29
Irregular fuel injection
Repair
Engine turns more
than maximum speed.
Impurities in governor
Repair
Engine stops suddenly
during operation.
Fuel shortage
Fault of nozzle
moving parts failure due to bad
lubrication
Add fuel and bleed air.
Repair or replace
Repair

Table of Contents