42
Detailed explanations
*1. Communication via USB
USS address:
Input 1 – 31
This address is required for communicating with LSPV inverter via USB.
Note:
If you change this parameter (address) and wish to save it, you must restart LSPV inverter!
The new address will only be active thereafter.
Protocol:
Input 1
USS and RPC protocol
*2. Communication via Ethernet
USS address:
Is factory-set and cannot be changed.
Protocol:
Input 0 or 1
0 = RTP protocol
1 = USS and RTP protocol
Protocol port:
Input 1024….65535; default setting 21062.
The port number is required for communication via Ethernet.
*3. Communication via RS485
USS address:
Input 1 – 31
This address is required for communicating with LSPV inverter via RS485.
Note
If you change this parameter (address) and wish to save it, you must restart LSPV inverter!
The new address will only be active thereafter.
Protocol polling via Ethernet:
Input 1, 2 and 3
1: USS and RTP protocol
2: Solar data systems
3: MeteoControl
©
*4. Portal monitoring
Activation:
Input 0 or 1
Parameter Off / On