Chapter 14 RS-422/485C function of K200S MASTER-K
14-8
14.7.5 Transmission period (D4449 ~ D4454)
The maximum, minimum, and previous period time of the first parameter setting is stored
in the D4449 ~ D4454. The period time means the interval from the start of previous
transmission to the start of current transmission.
Item Device area
Maximum D4449 ~ D4450
Minimum D4451 ~ D4452
Previous D4453 ~ D4454
14.8 Monitoring the communication status
User can monitor the RS-422/485 communication status with the high speed link 1 monitoring
window of KGL-WIN. (See the below figure) If the CPU type is not B type, the high speed link 1