8.3 Internal Memory
8.3.1 Special area for High-speed counter
Parameter and operation command area of built-in high-speed counter use a special K device.
If values set in parameter are changed, it works with the changed values. At the moment, makes sure
to use WRT command to save the changed value to flash. If not saved in flash, the changed values
with the power off => on and mode changed may not be maintained.
The following example shows that the internal preset values of CH1 set in parameter are changed by
program and saved in flash.
- Receiving an order command (M000), it moves (MOV) the new internal preset value (5000) to the
CH1 present area (K332).
- To save the changed settings into flash, it uses WRT command. At the moment, slot information is
set to ’0’ in case of built-in function.
Slot info Unused
0: High speed counter
1: determining a location
2: PID