ND30PNET-09 - User's Manual
50
6030/8030
7515
R
tg factor of L2 phase (tg=Q2/P2)
-
x
x
6032/8032
7516
R
THD U2*
%
x
x
6034/8034
7517
R
THD I2
%
x
x
6036/8036
7518
R
Voltage of L3 phase
V
x
x
6038/8038
7519
R
Current of L3 phase
A
x
6040/8040
7520
R
Active power of L3 phase
W
x
x
6042/8042
7521
R
Reactive power of L3 phase
VAr
x
x
6044/8044
7522
R
Apparent power of L3 phase
VA
x
x
6046/8046
7523
R
Factor of active power of L3 phase (PF3=P3/S3)
-
x
x
6048/8048
7524
R
tg factor of L3 phase (tg=Q3/P3)
-
x
x
6050/8050
7525
R
THD U3*
%
x
x
6052/8052
7526
R
THD I3
%
x
x
6054/8054
7527
R
Average 3-phase voltage
V
x
x
6056/8056
7528
R
Average 3-phase current
A
x
6058/8058
7529
R
3-phase active power (P1+P2+P3)
W
x
6060/8060
7530
R
3-phase reactive power (Q1+Q2+Q3)
VAr
x
6062/8062
7531
R
3-phase apparent power (S1+S2+S3)
VA
x
6064/8064
7532
R
3-phase active power factor (PF=P/S)
-
x
6066/8066
7533
R
tg factor 3-phase average (tg=Q/P)
-
x
6068/8068
7534
R
THD U* 3-phase average
%
x
x
6070/8070
7535
R
THD I 3-phase average
%
x
x
6072/8072
7536
R
Frequency
f
6074/8074
7537
R
Phase-to-phase voltage L
1-2
V
x
6076/8076
7538
R
Phase-to-phase voltage L
2-3
V
x
6078/8078
7539
R
Phase-to-phase voltage L
3-1
V
x
6080/8080
7540
R
Average phase-to-phase voltage L1-2
V
x
6082/8082
7541
R
averaged active power (P Demand)
W
x
6084/8084
7542
R
averaged apparent power (S Demand)
VA
x
6086/8086
7543
R
averaged current (I Demand)
A
x
6088/8088
7544
R
Current in neutral wire (calculated from
vectors)
A
x
x
6090/8090
7545
R
Active imported energy 3-phase (number
of register 7546 overflows, reset after
9999.9 MWh is reached)
100
MWh
6092/8092
7546
R
Active imported energy 3 phase (counter
up to 99999.99 kWh)
kWh
6094/8094
7547
R
Active exported energy 3-phase (number
of register 7548 overflows, reset after
9999.9 MWh is reached)
100
MWh
6096/8096
7548
R
Active exported energy 3 phase (counter up
to 99999.99 kWh)
kWh
6098/8098
7549
R
Reactive exported energy 3-phase
(number of register 7550 overflows, reset
after 9999.9 MVArh is reached)
100
MVArh
6100/8100
7550
R
Reactive inductive energy 3 phase
(counter up to 99999.99 kVArh)
kVArh
6102/8102
7551
R
Reactive capacitive energy 3-phase (number
of register 7552 overflows, reset after 9999.9
MVArh is reached)
100
MVArh
6104/8104
7552
R
Reactive capacitive energy 3 phase (counter up
to 99999.99 kVArh)
kVArh
6106/8106
7553
R
Apparent energy 3-phase (number of register
7554 overflows, reset after 9999.9 MVAh is
reached)
100
MVAh
6108/8108
7554
R
Apparent energy (caounter up to 99999.99
kVAh)
kVAh
6110/8110
7555
R
Time seconds
sec
6112/8112
7556
R
Time hours, minutes
6114/8114
7557
R