1-2
1.2 Data table
Des. Dim. VF1205 VF1207 VF1404 VF1406 VF1408 VF1410
MMMM MM
Output on motor side
Recom. rated power with P kW 1.1 1.5 1.5 2.2 3 4
4 pole standard motor
Device power S kVA 1.9 2.6 2.6 4.0 5.3 6.3
Rated current
1)
(230 V) I
N
A 4.5 6.2 - - - -
Rated current
1)
(400/460 V) I
N
A - - 3.5/3.1 5.5/4.7 7.2/6.3 8.9/7.7
Cont. current
1)
(230 V) 1.1xI
N
A 5.0 6.8 - - - -
Cont. current
1)
(400/460 V) 1.1xI
N
A - - 3.8/3.4 6.0/5.1 7.9/6.9 9.8/8.5
Overload current
1)
for 60s 1.5xI
N
A 6.8 9.3 5.3/4.7 8.3/7.7 10.8/9.5 13.3/11.6
Voltage U V 3 x 0...230 3 x 0 ... 400/460
Rotary field frequency f Hz 0...400
Frequency definition f % 0.1 of FMAX (0.05 Hz min.)
Load type - - ohmic/inductive
Short circuit proof - - at the terminals
Ground-fault proof - - according to each mains in.
Input on mains side
Mains voltage U V 1 x 230 +15/-20% 3 x 400/460 +10/-15%
Mains frequency f Hz 50/60 +/- 10%
Connection diameter A mm² max. 2.5
Recom. fusing I AT 1 x 16 1 x 16 3 x 10 3 x 10 3 x 16 3 x 16
Assymetry of mains volt. U % - 3 maximum
General
Operating mode - - 2 quadrats (4 quadrats)
2)
Peak braking power
2)
P
Sp
kW 1.65 max.
Cyclical braking mode
2)
P
eff
W90
Power loss
3)
P
V
W 65 82 80 100 120 150
Efficiency
3)
η %95959595 9595
Ambient conditions
Cooling air temperature T °C 0 ... 40 (to 1000 m and NN)
Ventilation type - - Convection force-ventilated
Relative air moisture - % 15 ... 85 not saturated
Power reduction in relation
to cooling air temperature -
∆P
T
-
2.5
% /°C
(in range 40 ... 50 °C)
Power reduction in relation
to the installation height
∆P
H
-
5
%
per 1000 m (in range 1000 ... 2000 m and NN)
Permissible vibration - - 2 g (IEC 68-2-6)
Mechanics
Weight (without packaging) - kg 3.75
Protection - - IP20, VBG4, NEMA 1
Installation - - upright wall mounting
1) based on the switching frequency of the end level of 8 kHz
2) only with BR1 design
3) with rated voltage and rated current