Loading...
3-1
3.2 Warning messages
(no fault reaction from the device)
Inverter malfunction
ATT1 Parameter alteration in online- mode (when motor running)
not allowed.
ATT2 Motor control via KEYPAD in online- mode not permitted.
ATT3 Access to Lust SMARTCARD in online- mode not permitted.
ATT4 System is in fault condition. Control via KEYPAD
not permitted.
ATT5 Motor data must be complete for the selected function
e.g. I R Compensation.
ERROR Invalid password
Acknowledge error by pressing start/enter-key.
Error with SMARTCARD-mode
ERR91 SMARTCARD is write-protected
ERR92 Error with plausiblity check.
ERR93 SMARTCARD not readable, inverter/servo-controller type incorrect.
ERR94 SMARTCARD not readable, parameter incompatible.
ERR96 Connection to SMARTCARD interrupted.
ERR97 SMARTCARD - data invalid (CS-Test).
ERR98 Insufficient memory on SMARTCARD (only MC6000).
Acknowledge error by pressing stop/return-key.
3 Operating and error diagnosis
3.1 Display
Position of LEDs:
41
42
43
44
45
46
n.c.
23
29
36
21
22
23
24
25
26
33
34
35
26
47
48
49
50
51
52
+
+
H2
H1
H1
yellow
H2
green
Meaning
Power off, no function
Power is switched on, after approxi-
mately 0.5 s Selftest, inverter ready
Inverter is started
Overload protection active
Error shut-down, flash rhythm H1
see chap. 3.2.2. Error message