6-17
6.7 Signal outputs
61-SOUTA Analog/frequency output
61-SOUTA Function
0/2/7/8/10/11 Outputs not active SOUTA = 0
, SOUTF = 24V
1 SOUTA = 0...10 V >> 0 ...FMAX proportional to the output frequency,
SOUTF = 24 V (not active)
3
FOUTF = 6-fold output frequency
,SOUTA = 0 (not active)
4 SOUTA = 0...10 V => Apparent current scaled to 100% of the device
rated current,
SOUTF= 24V (not active)
5 SOUTA=0...10 V => Effective current scaled to 100% of the
device rated current,
SOUTF= 24V (not active)
6 SOUTA=0...10 V => Effective power scaled to 100% of the device
rated power,
SOUTF= 24V (not active)
9 WE SOUTA as 61-SOUTA= 1,
SOUTF = 6-fold output frequency
12 SOUTA as 61-SOUTA= 4,
SOUTF = 6-fold output frequency
13 SOUTA as 61-SOUTA= 5,
SOUTF = 6-fold output frequency
14 SOUTA as 61-SOUTA= 6,
SOUTF = 6-fold output frequency
Comment:
If the outputs SOUTA and SOUTF simultaneously in use
(Param. 61-SOUTA = 9,12,13,14), the quality of the signals is poorer
(Basic frequency = 60Hz). If output SOUTA is in use alone
(Param. 61-SOUTA = 1,4,5,6), the quality of the signals is better (Basic
frequency = 1.6 kHz).