EasyManua.ls Logo

Lust SMARTDRIVE VF1205M - Inverter-Type Dependent and Nationally Related Parameters

Default Icon
78 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5-4
5.3 Inverter-type dependent and nationally-related parameters
Abbrev. Page Name Unit WE- WE- Inverter type
AB
44-VN1 6-10 Voltage rated point 1 V 230 230 VF1205M...VF1207M
44-VN1 6-10 Voltage rated point 1 V 400 460 VF1404M...VF1410M
47-VN2 6-11 Voltage rated point 2 V 230 230 VF1203M...VF1207M
47-VN2 6-11 Voltage rated point 2 V 400 460 VF1404M...VF1410M
50-IN 6-13 Motor rated current, A 4.5 4.5 VF1205M
56-ILIM 6-16 Current limit, A 6.2 6.2 VF1207M
59-TRIP 6-16 I x t monitoring A 3.5 3.4 VF1404M
A 5.4 4.8 VF1406M
A 7.1 6.3 VF1408M
A 8.9 7.7 VF1410M
53-KIXR 6-14 Corr. factor IR comp. - 7 7 VF1205M
53-KIXR 6-14 Corr. factor IR comp. - 4 4 VF1207M
53-KIXR 6-14 Corr. factor IR comp. - 18 18 VF1404M
53-KIXR 6-14 Corr. factor IR comp. - 12 12 VF1406M
53-KIXR 6-14 Corr. factor IR comp. - 8 8 VF1408M
53-KIXR 6-14 Corr. factor IR comp. - 8 8 VF1410M
54-KSC 6-14 Corr. factor slip comp. % 6.7 6.7 VF1205M
54-KSC 6-14 Corr. factor slip comp. % 6 6 VF1207M
54-KSC 6-14 Corr. factor slip comp. % 6 6 VF1404M
54-KSC 6-14 Corr. factor slip comp. % 5.3 5.3 VF1406M
54-KSC 6-14 Corr. factor slip comp. % 5.3 5.3 VF1408M, VF1410M
Solely nationally related parameters
22-FMAX1 6-7 Maximum frequency 1 Hz 50 60
29-FMAX2 6-7 Maximum frequency 2 Hz 50 60
43-FN1 6-10 Frequency rated point 1 Hz 50 60
46-FN2 6-11 Frequency rated point 2 Hz 50 60
52-NN 6-13 Rated speed UPM 1390 1710
Factory setting (FS):
The factory setting can be adjusted with the KEYPAD in the PARA menu. To
this end parameter 71-PROG must be set to 1 (WE-A e.g. for Europe) or
71-PROG to 4 (WE-B e.g. for USA).