6-6
13-V Output voltage [V]
Displays the actual output voltage. The output voltage is kept constant
independently of the DC-link voltage (DC-link compensation), if a drive
reserve is available. After a error shut-down, the actual value existing
immediately before shut-down is saved (Hold-Function).
14-IS Phase current [A]
Displays the actual apparent phase current. After an error shut-down,
the actual value existing immediately before shut-down is saved (Hold-
Function).
15-IW Effective current [A]
Displays the actual effective phase current. After an error shut-down, the
actual value existing immediately before shut-down is saved (Hold-
Function).
16-PW Effective power [W]
Displays the effective power from the inverter.
17-VZK DC-link voltage [VDC]
Displays the actual DC-link voltage. After a error shut-down, the actual
value existing immediately before shut-down is saved (Hold-Function).
18-TIME Switch-on duration from reset [0.1 hour]
Displays the switch-on duration since last reconnection to mains.
19-TOP Running time [hours]
Displays the total running time. The maximum value is 60000 hours.
Once this level is reached, there is no further increase.