J
PG 1: ADDED: NOTE 8, RMVD:
EXPLO SION PROOF & DUST
I
GN ITION PROOF FROM H AZARD-
O
US LO CATION, CH GD: G W AS 6;
P
G 2 CHGD TO PG 3, ADDED NEW
PG 2; PG 3 ADDED: SMART ESII
M
OD ULEVEL & ES9 TO H AZARDOUS
LO CATION S & RMVD GSH, GSK,
G
SQ , GST, GS4, RSQ , RST, RSZ;
ADDED: ILLUSTRATION & NOTE 9,
CHGD NON HAZARDO US LO CATION:
V
t & It W ERE V+ & Ie RESP.
SC 6-99 3057-986
ENTITY
V
max = 28.6V
Imax = 140m A
Ci = 5nF
Li = 434µH
P
max = 1W
ALTERNATIVELY - FM ONLY
Vmax = 22V
Imax = 165 m A
C
i = 5nF
L
i = 43µH
Pmax = 1W
I
NTRINSICALLY SAFE CONNE CTION S CLASS I,II,III DIV 1 GROUPS B,C,D,E,F & G
NON -INCENDIVE CLASS I DIV 2 GROU PS A,B,C,D
CLASS II DIV 2 GROUPS E,F,G
(F & G ONLY FOR FM )
ALTERNATIVELY - FM ONLY
Voc ≤ 22V Ca ≥ 5nF
I
sc ≤ 140m A La ≥ 434µH
T4 Ta = 71°C
M
RC 01-02
3
051-020
ADDED:
"ALTERNATIVELY - FM ONLY"
REMOVED: MODELS KSQ , KST,
KSZ, KZQ AND KZT
M
MM
P/N 99-5031-000
L
PAGE 1 - CH G'D: LIM ITING
V
ALUES 5nF W AS 5pF, 434µH
W AS 434nF. BOTH PAGES -
C
HG 'D: ENTITY 434µH W AS
434nH . PAGE 2 - ADDED TO
N
OTE 7 SECOND CSA W ARNING .
JM JARAS
1
-18-00
3051-004
P
.S.SNIDER
99-5031
99-5031
NONE
3
/8/99D.PASHO LK
4/28/99J.M .JARAS
3
057-515
5
-14-99
SYSTEM DRAW ING
ES II / EZ MODULEVEL
S
MART ES II / EZ MODULEVEL
HAZARDOUS LO CATION SAFE LOCATION
8. REMOTE MOU NT LVDT & ELECTRONICS H O USING
MUST BE IN STALLED EXPLO SION PROOF.
9. NRTL LISTED DUST TIGH T SEALS MUST BE
USED W HEN INSTALLED IN CLASS II & III
ENVIRONMENT S.
LIM ITING VALUES
V
oc ≤ 28.6V Ca ≥ 5nF
I
sc ≤ 140m A La ≥ 434µH
NOTE:
1
. ANY CHANGES TO TH IS DRAW ING MUST BE SUBM ITTED TO FACTORY MU TUAL & CSA
PER SPI SE0-006.
2. MANUFACTURE'S INSTRUCTION S SUPPLIED W ITH THE PROTECTIVE BARRIER, CEC (CSA)
OR THE NEC MUST BE FO LLOW ED W HEN INSTALLING THIS EQUIPMENT.
3. FOR IN STALLATION GUIDAN CE, SEE ANSI/ISA RP12.6.
4
. FOR CSA: EXIA INTRINSICALLY SAFE/SECURITE INTRIN SEQ U E.
5. FOR CSA: W ARNING -EXPLOSION HAZARD-SUBSTITUTION OF COMPONENT S MAY
IMPA IR SUITABILITY FOR HAZARDO US LO CATION S.
FOR CSA: W ARNING-EXPLO SION HAZARD- DO NOT DISCONNECT EQ UIPMENT
UN LESS POW ER HAS BEEN SW ITCHED OFF OR THE AREA IS KNO W N TO BE
NON-HAZARDO US.
6. FOR SUPPLY CONNECTION S USE W IRE SUITABLE FOR TH E OPERATING
TEMPERATU RE. FOR 71°C AMBIENT USE W IRE W ITH A MINIM UM
TEMPERATU RE RATING OF 75°C.
7. TH E TRANSM ITTER MAY ALSO BE IN STALLED IN CLASS I, DIV.2,
GROUPS A,B,C,& D; CLASS II, DIV.2, GROUPS E,F,& G (F & G ONLY
FOR FMR C); CLASS III, DIV.2, LOCATION S AND DOES NOT REQ UIRE
CONNECTION TO A PROTECTIVE BARRIER W H EN IN STALLED PER CEC
(FOR CSA) OR NEC (FOR FMR C) AND W HEN CONNE CTED TO A POW ER
SOURCE NOT EXCEEDING 30 VDC.
T
HE VOLTAGE (Vmax) AND CU RRENT (Imax)
W H ICH TH E TRANSM ITTER CAN RECEIVE
M UST BE EQ UAL TO OR GREATER THAN
TH E MAXIM UM OPEN CIRCUIT VOLTAGE
(
Voc OR Vt) AND TH E MAXIM UM SHORT CIRCUIT
C
URRENT (Isc OR It) W H ICH CAN BE DELIVERED
BY THE SOU RCE DEVICE. IN ADDITION, THE
M
A XIM UM CAPACITANCE (Ci) AND INDUCTANCE
(
Li) OF THE LOAD AND THE CAPACITANCE
AND IND U CTANCE OF THE INTERCONNECTING
W IRING, MUST BE EQ U AL TO OR LESS TH AN
T
HE CAPACITANCE (Ca) OR TH E IND UCTANCE
(
La) W H ICH CAN BE DRIVEN BY THE SOU RCE
D
EVICE.
MODE LS APPROVED
x Exx-xxxx- RSQ, RST, RSZ FOR SMART ES II
RZQ, RZT, FOR EZ MODULEVEL
5057-008
D
PP 3/99
H
1
2
P
G. 1: REDRAW N ON CAD.
ADDED: PG. 2, P/N -002.
W ITHO UT METER
W ITH METER
(W INDO W ED)
TRANSM ITTER
IN STRUMENT
S
EALED NIPPLE
(EPOXY FILLED)
C
OND UIT JUN CTION
F
ITTING
INTRINSICALLY
S
AFE
B
ARRIER
K
PG.1 & 2: ADDED ES II TO
TITLE, T4 Ta=71°C & EZ TO
TO SMART ES II MODULEVEL
CALLO U T. ENTITY CI W AS 5pF.
REVISED MODELS APPROVED.
DRW G. W AS 3 PAGES.
JS 11-99
3057-994
AGENCY LISTED
DRAW ING
QA APPROVAL
D
RAW ING REQ UIRE
ALL REVISION S TO TH IS
R
5300 BELMONT ROAD, DOW NERS GROVE,
ILLINO IS 60515 / AREA 630 / 969-4000
OR BETTER
EDGES, MAX. ALLOW ED .032(0,81)
I
NSIDE RADII .032(0,81)R.
A
LL FINISHES 125
"
mm " DIMEN SION S IN MILLIMETERS
TOLERANCES:
2
PL. IN. DEC. ± 0.015 IN .(0,4mm )
3
PL. IN. DEC. ± 0.005 IN .(0,2mm )
A
N
G
U
L
A
R
±
2
°
REMOVE ALL BURRS AND SH ARP
PLAIN DIMEN SION S IN INCHES; () OR
UN LESS OTH ERW ISE SPECIFIED:
T
HIS DRAW ING IS THE EXCLUSIVE PROPERTY
O
F MAGNETROL INTERNATIONA L. NO USE
W HATSOEVER OF TH E INFORMATION CON-
TAINED HEREON, NOR REPRODUCTION IN
W HOLE OR IN PART MAY BE MADE W ITHO UT
THE EXPRESS W RITTEN PERMISSION OF:
MAGNETRO L INTERNATIONA L
R
EVISION S
DESCRIPTION BY & DATE CH ANGE NO.
MATERIAL
RAW MATL PART NO.
HEAT TREAT
FIN ISH
TITLE
DRAW N
CHKD
APPD
PROJ NO.
DATE
DATE
DATE
SKETCH NO.
SCALE PAGE O F
DW G
SIZE
C
SYM
THIRD ANGLE
PROJECTION
IN
(mm )
DW G
SIZE
C
P/N 99-5031-000
RC 1-02
3051-020
M
ENTITY
Vmax = 28.6V
Imax = 140m A
Ci = 5nF
Li = 434µH
Pmax = 1W
ALTERNATIVELY - FM ON LY
Vmax = 22V
Imax = 165m A
Ci = 5nF
Li = 434µH
Pmax = 1W
M
1) Barriers m ust be CSA Certified and FM approved.
2) M anufacturers installation instructions supplied w ith the protective barrier and
the CEC (for CSA) or the NEC and ANSI/ISA RP 12.6 (For FM RC) m ust be follow ed
wh en installing the equipm ent.
3) Control equipm ent connected to protective barriers m ust not use or generate m ore
than 250 Vdc or Vrm s.
4) NRTL listed dust tight seals m ust be used wh en device is installed in
Class II & III environm ents.
5) No revisions to this draw ing w ithout FM RC and CSA approval.
6) For CSA: Exia Intrinsically Safe / Securite Intrinseque
7) For CSA: W arning Explosion H azard Substitution of com ponents ma y im pair
suitability for hazardous Locations.
For CSA: W arning Explosion H azard D o not disconnect equipm ent unless
power has been sw itched off or the area is know n to be non-hazardous.
8) For supply connections, use w ire suitable for operating tem perature.
For 71°C am bient, use w ire w ith a m inim um tem perature rating of 75°C.
9) The transm itter ma y also be installed in Class I D iv 2 groups A,B,C,D ,
Class II, D iv 2 Groups E,F & G (F&G only for FM RC); Class III, D iv 2
locations and does not require connection to a protective barrier wh en
installed per CEC (for CSA) or NEC (for FM RC) and wh en connected to a
power source not exceeding 30VDC.
L
im iting Values
Voc <= 28.6V Ca >= 5 nf + Ccable
Isc <= 140 m A La >= 434 uH + Lcable
ALTERNATIVLY - FM ON LY
Voc <= 22V Ca >= 5 nf + Ccable
Isc <= 165 m A La >= 434 uH + Lcable
M
P.S.SNIDER
99-5031
99-5031
NO N E
3/8/99D.PASHO LK
4/28/99J.M .JARAS
3057-515
5-14-99
SYSTEM D RAW ING
ES II / EZ M O D ULEVEL
HAZARD O US LOCATIONS
Intrinsically Safe for CL I, D iv. 1 Groups A B C D
CL II, D iv. 1 Groups E F G
CL III NEM A 4X (FM ) TYPE 4X (CSA)
T4 Ta = 71°C
T
he voltage (Vmax) and current (Imax) wh ich the transm itter can receive
m ust be equal to or greater than the maxim um open circuit voltage
NO TES:
NO N HAZARD OUS LO CATIONS
(Voc or Vt) and the maxim um short circuit current (Isc or It) wh ich
can be delivered by the source device. In addition, the maxim um
c
apacitance (Ci) and inductance (Li) of the load and the capacitance
and inductance of the interconnecting w iring, m ust be equal to or
less than the capacitance (Ca) or the inductance (La) wh ich can be
driven by the source device.
S
EE SH EET 1 FO R REV.
22
W ITHO UT M ETER
S
EALED NIPPLE
(EPO XY FILLED)
CON D U IT JU NCTIO N
FITTING
TRANSM ITTER
IN STRUM ENT
W ITH M ETER
(W IND O W ED)
I
NTRINSICALLY
SA FE
BARRIER
S
M ART ES II / EZ M OD ULEVEL
Lim iting Values
x M O D EL Exx-xxxx- ESD, ESI, ESJ, ESH, ESK, ES8 OR ES9 FOR SM ART ES II
EZD , EZI, EZH, O R EZK FO R EZ M O D ULEVEL
AGENCY LISTED
DRAW ING
Q A APPRO VAL
DRAW IN G REQ U IRE
ALL REVISIO NS TO THIS
R
5300 BELM O NT ROAD , D O W NERS GROVE,
ILLINOIS 60515 / A REA 630 / 969-4000
OR BETTER
EDG ES, M AX. A LLOW ED .032(0,81)
INSID E RADII .032(0,81)R.
ALL FINISHES 125
"mm " D IM ENSIO N S IN M ILLIM ETERS
TO LERANCES:
2 PL. IN. D EC. ± 0.015 IN .(0,4mm )
3 PL. IN. D EC. ± 0.005 IN .(0,2mm )
A
N
G
U
L
A
R
±
2
°
REM O VE ALL BURRS AN D SH ARP
PLAIN DIM ENSIO NS IN INCHES; () O R
UN LESS O THERW ISE SPECIFIED :
THIS D RAW ING IS THE EXCLUSIVE PROPERTY
OF M AGN ETROL INTERNATIONAL. NO USE
W HATSO EVER OF THE IN FORM ATIO N CON-
T
AINED HEREON, NO R REPRODU CTIO N IN
W HOLE OR IN PART M AY BE M AD E W ITHO UT
T
HE EXPRESS W RITTEN PERM ISSION O F:
M AGNETROL INTERNATION AL
R
EVISIO NS
DESCRIPTION BY & DATE CHANG E NO .
M ATERIAL
RAW M ATL PART NO .
HEAT TREAT
FIN ISH
TITLE
DRAW N
CHKD
APPD
PROJ NO.
DATE
DATE
DATE
SKETCH NO.
SCALE PAGE OF
DW G
SIZE
C
SYM
THIRD ANGLE
PROJECTION
IN
(mm )
DW G
SIZE
C