OPERATING CONTROLS AND PROCEDURES 18000 OPERATOR MANUAL
3-46
Published 12-05-17, Control # 032-23
Jacking Controls
3–Left Front Jacking Switch
4–Right Front Jacking Switch
5–Left Rear Jacking Switch
6–Right Rear Jacking Switch
Move selected toggle UP and hold to EXTEND jacking
cylinder.
Release toggle to CENTER to STOP jacking cylinder.
Move selected toggle DOWN and hold to RETRACT jacking
cylinder.
7– All Jacking Switch
Move toggle UP and hold to EXTEND all jacking cylinders at
same time.
Release toggle to CENTER to STOP jacking cylinders.
Move toggle DOWN and hold to RETRACT all jacking
cylinders at same time.
NOTE When the ALL jacking switch is used, the crane’s
programmable controller will attempt to adjust the
jacking cylinders to maintain or return the rotating
bed to level as sensed by the rotating bed level
sender.
Prior to using the ALL jacking switch, verify the
accuracy of the rotating bed level sender with an
user furnished digital level. The TILT RIGHT and
TILT FRONT angles shown on the digital display
should be the same as the angles shown on the
digital level.
The CRANE LEVEL operating limit will appear on
the digital display and the swing and travel alarm
will sound if the rotating bed gets 3° out of level
while jacking.
• Operation does not stop automatically when
this alarm comes on.
• When this alarm comes on, operator shall
stop jacking and level rotating bed using
individual jacking switches.
If the rotating bed level sender indicates that the
rotating bed is more than 4.7° out of level, the
CRANE LEVEL SENSOR system fault will appear
on the digital display, the swing and travel alarm will
sound, and the ALL jacks switch will be disabled.
The rotating bed should then be leveled using the
individual jacking switches, and the accuracy of the
rotating bed level sender should be checked.
Boom Pins Control
8–Boom Pins Switch
Move toggle UP and hold to ENGAGE boom hinge pins.
Release toggle to CENTER to STOP pins.
Move toggle DOWN and hold to DISENGAGE boom hinge
pins.
Rotating Frame Controls
9–Front Rotating Frame Pins Switch
10–Rear Rotating Frame Pins Switch
Move selected toggle UP and hold to ENGAGE rotating bed
pins.
Release toggle to CENTER to STOP.
Move selected toggle DOWN and hold to DISENGAGE
rotating bed pins.
Mast Controls
11–Mast Pins Switch (
Fixed Mast)
Move toggle UP and hold to ENGAGE fixed mast pins.
Release toggle to CENTER to STOP.
Move toggle DOWN and hold to DISENGAGE main mast
pins.
12–Mast Switch (Live Mast Arms)
Move toggle UP and hold to RAISE live mast arms with mast
cylinders.
Release toggle to CENTER to STOP mast cylinders. Valves
on the cylinders lock them in position.
Move toggle DOWN and hold to LOWER live mast arms with
mast cylinders.
Read Crane Assembly and Disassembly in Section 4 for live
mast raising and lowering instructions.
CAUTION
Machinery Damage!
To avoid damage to jacking cylinders, fully retract them
before traveling.
WARNING
Falling Load Hazard!
To prevent boom or boom butt from falling off crane:
• Do not disengage boom hinge pins until boom butt is
properly supported on stands at ground level. Boom/
boom butt could fall off crane.
Read Boom Rigging Guide in Section 4 of this Manual.