OPERATING CONTROLS AND PROCEDURES 18000 OPERATOR MANUAL
3-84
Published 12-05-17, Control # 032-23
Item Description
1 Receptacle – 240 volt
2 Power Cord (Customer Supplied)
3 Circuit Breaker Load Center
3a Main – 50 amp
3b Engine Coolant and Oil Heaters – 20 amp
3c Cab Console and Battery Pad Heaters – 15 amp
3d Hydraulic Tank Heater – 15 amp
4 Right Front Control Console Heater – 240 volt, 125 watt
5 Battery Pad Heaters (2) – 240 volt, 75 watt
6 Engine Coolant Heater – 240 volt, 4,000 watt
7 Engine Oil Heater – 240 volt, 300 watt
8 Hydraulic Tank Heaters (1 Current, 5 Past) –
120 or 240 volt, 500 watt
9 Hydraulic Tank Heating Blanket
A16692-1
1
3
FIGURE 3-53
3a
2
4
5
6
7
8
3b 3c 3d
9