Maintenance work on the carrier
7.4 Fuel system
09.03.2018
Maintenance manual 3 302 746 en 7 - 31
GMK5200-1
7.4.3 Replacing fuel filter 2
Spare parts and
tools
Receptacle, approx. 5 l (1.5 gal); à p. 2 - 4.
Torque wrench for torque of 15 Nm (11 lbf ft).
Prerequisites The truck crane must be level and on outriggers; à Operating manual.
The main boom must be fully raised; à Operating manual.
The engine must be switched off and secured against unauthorised use;
à p. 2 - 3.
The fuel must be drained from the fuel filter 1; à p. 7 - 29.
If the fuel is contaminated: Reduce the maintenance interval.
Changing
Place a receptacle underneath the filter.
Remove the cover (1).
Remove the old filter (2) from the casing.
Place the old filter (2) in the receptacle.
Insert a new filter (2) into the casing.
Attach the cover (1) – torque 15 Nm
(11 lbf ft);
à Engine manufacturer's documen-
tation
.
Remove the receptacle.
s
M 12
Designation Quantity GROVE part no.
Filter (small) 1 04161566
Alternatively:
Set of both filters 1 + 2 (large + small)
1 04180966
O
Risk of environmental damage due to leaking consumables.
Always let consumables drain into suitable receptacles. Wipe up any con-
sumables that have leaked.
Store/dispose of consumables and any soaked equipment properly.
Ask about the applicable regulations.