Maintenance work on the superstructure
8.8 Hoist ropes
09.03.2018
Maintenance manual 3 302 746 en 8 - 65
GMK5200-1
H
Observe the hook block when unreeling.
The hook block must not rotate.
• Set the lowering limit switch; à p. 8 - 65.
• Run in the new rope with small loads so that the rope can settle on the
hoist drum.
8.8.6 Setting the lowering limit switch
A lowering limit switch is mounted both on the main hoist and on the aux-
iliary hoist.
Spare parts and
tools
Prerequisites – A hook block must be reeved 5-fold; à Operating manual.
– The main boom is fully raised and extended; à Operating manual.
– The hook block is lowered until only five turns of the rope remain on the
hoist drum.
s
G
Risk of accidents if the lowering limit switch is set incorrectly.
After inserting a new rope, the lowering limit switch must always be reset.
In this way you avoid the lowering limit switch switching off too late or not
at all, the rope being damaged and the load being dropped.
Designation Quantity GROVE part no.
Cover gasket 2 02315305

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc Grove GMK 5200-1 and is the answer not in the manual?

Manitowoc Grove GMK 5200-1 Specifications

General IconGeneral
BrandManitowoc
ModelGrove GMK 5200-1
CategoryConstruction Equipment
LanguageEnglish

Related product manuals