Maintenance work on the carrier
7.7 Transfer case
7 - 50 3 302 746 en Maintenance manual
GMK5200-1
09.03.2018
Checking
Remove the drain plug (1).
Check that the oil reaches the lower edge of
the opening.
Fit a new gasket and tighten the drain plug.
If the oil level is too low
Top up the oil; à p. 7 - 51.
7.7.3 Changing the oil
Oil, spare parts,
tools
Receptacle, approx. 15 l (4.0 gal); à p. 2 - 4.
Prerequisites The truck crane must be raised on outriggers or parked over an inspection
pit.
The engine must be switched off and secured against unauthorised use;
à p. 2 - 3.
M 6
Gear oil in
litres (gal)
Designation to
DIN 51502
Specification
Classification
GROVE part no.
12.8 (3.4)
for 10 x 6 x 10
14.0 (3.7)
for 10 x 8 x 10
C - LPF MIL-L 2105 B
API-GL-5
Viscosity:
Hyp SAE 90
ISO - VG 220
00552891
Designation Quantity GROVE part no.
Gasket 16 x 20 Cu DIN 7603 1 00117134
Gasket 30 x 36 Cu DIN 7603 1 00117151