Maintenance work on the carrier
7.6 Transmission
7 - 44 3 302 746 en Maintenance manual
GMK5200-1
09.03.2018
Remove the drain screw (2).
Place a receptacle under screws (1) and (3).
Unscrew the screws (1) and (3) and allow the
oil to drain off.
Clean the drain screws.
Replace the gaskets and tighten the drain
screw (3) to torque 55 Nm (40.5 lbf ft).
Replace the gaskets and tighten the drain
screw (1) to torque 24 Nm (17.7 lbf ft).
Changing the filter
Remove the cover (1).
Remove the old filter (2) from the casing.
Place the old filter (2) in the receptacle.
Insert a new filter (2) into the casing.
Replace the cover gasket and the vent valve.
Bolt the cover (1) on.
O
Risk of environmental damage due to leaking consumables.
Always let consumables drain into suitable receptacles. Wipe up any con-
sumables that have leaked.
Store/dispose of consumables and any soaked equipment properly.
Ask about the applicable regulations.