Maintenance work on the carrier
7.17 Electrical system
09.03.2018
Maintenance manual 3 302 746 en 7 - 125
GMK5200-1
Checking the connecting terminals
Keep the batteries clean and dry.
Remove any dirty connecting terminals (1)
and clean them.
Fasten any loose connecting terminals.
Grease the connecting terminals and poles
lightly with a special battery terminal
grease.
Checking the acid level
Batteries without caps (1) are maintenance-
free.
Remove all caps (1).
The acid level must be above the plates.
If the acid level is too low
Top it up using only distilled water until the
plates are covered.
Tightly bolt on all caps (1).
After checking
Push the battery box in.
Switch on the battery master switch (1);
à Operating manual.
Check the timers on the tachograph and on
the auxiliary heater;
à Operating manual.
Enter the code for the radio; à Separate
operating manual
.