Maintenance work on the superstructure
8.4 Slewing gear
09.03.2018
Maintenance manual 3 302 746 en 8 - 17
GMK5200-1
Check the
following
When checking the slewing gear brake you must perform the slewing move-
ment against the slewing gear brake.
Switch off the engine.
Remove the coil (1) from the valve Y 2304.
The slewing gear brake will now not be
released when the slewing gear is switched
on.
Start the engine and switch on the slewing gear.
Open the CCS menu Hydraulic pressure.
Display (1) will show the pressure in the slewing gear's hydraulic circuit.
Move the control lever slowly to the stop and wait until the pressure in the
hydraulic circuit has risen to approx. 200 bar (approx. 2,900 psi).
If the superstructure still does not slew, the braking force of the slew-
ing gear brake is adequate.
If the superstructure does slew, the slewing gear brake is defective and
must be repaired immediately by
Manitowoc Crane Care or an author-
ised GROVE dealer.