Maintenance work on the superstructure
8.4 Slewing gear
8 - 20 3 302 746 en Maintenance manual
GMK5200-1
09.03.2018
Draining oil
Remove the plate (1).
Place a container under the screws (2).
Unscrew the filter (4) and screws (3) and (2).
Drain the oil.
Replace the gasket and tighten the
screws (2).
Topping up oil
Top up the oil through the filler neck (4)
until oil is visible in the inspection
glass (5).
Replace the gaskets and tighten the
screw (3) and the filter (4).
Replace the plate (1).
Checking the oil Check the waste oil that was drained from the slewing gears for abrasion
particles, or have it tested at a laboratory.
Pour the waste oil through a clean filter mat.
Examine the oil, i.e. the residues on the filter mat using a magnifying
glass.
If you find abrasion particles or solid materials on the mat, the slewing gear
transmission must be removed and inspected by the manufacturer.