Maintenance work on the superstructure
8.6 Hydraulic system
8 - 46 3 302 746 en Maintenance manual
GMK5200-1
09.03.2018
Establishing the
operating
conditions
After having changed the oil filters and topping up the oil, you must
re-establish the operating conditions.
Opening the valve
Open the valve – lever (1) parallel to the line.
Start the engine.
Carry out all hydraulic functions several times to remove any air in the
system.
Check that none of the oil filters is leaking.
Check the oil level through the inspection glass on the hydraulic oil tank.
Top up oil, if necessary;
à p. 8 - 45.
S
Risk of damage to the hydraulic pumps.
Open the valve prior to starting the engine.
This prevents damage to the hydraulic pumps.

Table of Contents