The permissible temperature range while in operation varies from +15 °C to +30 °C.
During storage or transportation, the ambient temperature can range between -20 °C and
+70 °C. If condensation occurs during storage or transportation, the device must be
acclimated for about 2 hours and dried by means of an appropriate circulation. Thereafter,
the operation is permitted.
Nominal data with tolerance disclosures are valid after a warm-up time of at least 30 minutes
at an ambient temperature of 23° C. All values without tolerance disclosures are
recommended values of an average device.
2.5 Maintenance
The outside of the appliance should be cleaned regularly with a soft, lint-free duster. Please
make sure that the device is turned off and disconnected from the power supply, before you
clean it.
Cleaning the device or its parts with alcohol or other solvents is not allowed, except for
cleaning the removable brass cups.
The display may only be cleaned using water or a suitable glass cleaner (but not with alcohol
or other washing solvents).
The coloured banana cables, the ground cable and the two earthing cables should be
checked regularly with the built-in cable tester.
2.6 Mains Voltage
The device operates with an AC voltage of 100 V to 240 V with a frequency from 47 to 63 Hz.
A supply mains voltage switching is not necessary.
2.7 Mains Input Fuses
The device has 2 fuses: 3,15AT. One fuse (fuse A) ensures the charge cycle, while the
second fuse (fuse B) ensures normal operation.
Only micro fuses with 3,15AT may be used.
If a fuse is blown repeatedly, a repair is needed. The device is to be shut down in this case.