ECODRIVE DKC01.1/DKC11.1 Drive Controllers
DOK-ECODRV-ASE-02VRS**-WAR1-EN-P 07.96 Description of Diagnostic Letters F... and E... 2-5
F248 Low Battery Voltage
Cause:
The connected motor has an absolute encoder. The absolute position
information is stored in the motor feedback. This memory has a battery
powered backup for the electronic circuit. The battery is designed for a
operating life of 10 years. If the battery voltage drops below 2.8 V, this
message appears. The absolute encoder function is preserved for about
2 weeks.
Instructions for Exchanging Batteries
Have the following tools and accessories ready:
Torx screwdriver,size 10
Needle nose pliers, torque wrench
New packaged battery (Part no.: 257101)
If the control voltage of the installed battery is turned off, the absolute
position is lost.
The absolute position must be re-established through the process of the
command Set Absolute Measurement.
F262 Status Outputs Short Circuited
Description:
If the status outputs of the DKC are short circuited, the drive controller will
issue an error.
Cause:
Short circuited outputs (X2/6, X2/7, X2/8, X2/9, X2/10, X2/20, X2/21,
X2/22)
Remedy:
Eliminate short circuit